Home Customize Instructions Contact Category 6 Category 7   Home Search Contact Us
 
SOQ
Warranty
Credit App.
News
Email Us

Air Strippers
O/W Separators
SVE Air Sparging
Dual Phase Extr.
Carbon Systems
Recovery Pumps
Skimmer Systems
SolarNAPL
SEP IV Electric
Certifications
Pictures

NC OFFICE

FL OFFICE

TX OFFICE

NY OFFICE

 



 

 

 

 

   

PRM Hand Held Rental Equipment

 

 
Photovac * Flame Ionization Detector

Detect up to 50,000 ppm VOCs including methane. For accurate, reliable detection of VOCs in fugitive emissions or environmental applications, the Photovac Micro FID is the right choice.

 
Horiba * U-10 Water Quality Checker

Brings laboratory accuracy and the ease of push-button operation to water quality

measurement in the field. The instrument measures six parameters: pH, temperature,

dissolved oxygen, electrolytic conductivity, turbidity and salinity.  An automatic salinity correction factor allows the U-10 to measure DO in either fresh or salt water.  A flow-through cell enables in-situ measurement from monitoring wells.

 

 
Horiba * U-22 XD Water Quality Monitor

Is an excellent tool for groundwater monitoring applications?  The sensor has also been redesigned with a narrow 1.8 inch diameter. The Horiba U-22 offers highly accurate, simultaneous analysis of 10 parameters, including pH, dissolved oxygen, conductivity, salinity, total dissolved solids (TDS), seawater specific gravity, temperature, turbidity, depth and oxidation reduction potential (ORP).

The flow-through cell is a 500 ml reservoir that permits in-line analysis of purge water before sampling.

 

 
Testwell * Interface Meter

Two separate sensitivity controls for the water sensing and fluid sensing circuits allow the user complete control over the performance of the instrument. 1/100 ft or 1mm & 5x more accurate than white tapes with a Kynar or Polyethylene jacket.  Measure LNAPLs & DNAPLs down to ½ mm or 1/200 of a foot with pressure proof  stainless steel probe.

 

 
Testwell * Water Level Meter

Unique 7/16” diameter probe displaces less than ½ mm of water when used in ½” ID wells. Five times more accurate than white tapes with complete polyethylene jacket to protect 1/100 ft or 1mm graduations and stranded stainless steel conductors. The zero displacement unit is based on the popular SST-Series probe and tape, and the LR-Rugged Reel. The SST probe and tape and LR-Reel have been Ranked #1 for accuracy, durability and ease of use since 1995

 

 
RKI EAGLE * 4 Gas Monitor LEL/02/H2S/CO

The Eagle is ideal for any industrial, UST, or confined space work. It has a internal sampling pump that is able to draw samples from over 125 feet and comes with a 15’ sample lead that has a liquid shutoff switch to prevent contamination of the instrument.  The ranges for this unit are: 0-100% LEL or 0-50,000ppm, 0-40% O2, 0-100ppm H2S,  0-500ppm CO. (Intrinsically safe for Class I, Division 1, Groups A, B, C, D) This unit has a methane elimination switch that will automatically filter methane from detection.

 

 
RKI EAGLE * 2 Gas Monitor LEL/02

Handheld instrument with battery that will continuously operate for 18 hours. This unit has a methane elimination switch that will automatically filter methane from detection. The ranges for this unit are: 0-100% LEL or 0-50,000ppm, 0-40% O2. (Intrinsically safe for Class I, Division 1, Groups A, B, C, D).

 

 
LUDLUM * Model 3 Radiation Monitor

The Ludlum Model 3 Survey Meter with Model 44-9 GM Pancake Probe detects alpha, beta and measures gamma radiation levels form 0-200 mR/hr.  It is typically used to measure lower levels of radiation, and detects ion contamination levels. The  pancake detector is intended to be used only when surveying for contamination. Also includes 44-2 Gamma Scintillator for high energy gamma detection. Typically 175 cpm/micro R/hr (Cs-137)

 

 
RAE SYSTEMS * Mini-Rae 2000

The rugged Mini-RAE 2000 is the most popular hand-held photo ionization detector (PID) for VOC measurement ranging from 0-10,000 parts-per-million. With over 100.  Correction Factors built into the Mini-RAE 2000’s memory and the largest printed list of Correction Factors in the world (300+), RAE Systems offers the ability to accurately measure more ionizable chemicals than any other PID! When a gas is selected from Mini-RAE 2000’s library its alarm points are automatically loaded into the meter. 

 

 
OAKTON * Ph/Con/10 Meter

Meter includes a versatile multi-sensor probe—there’s no need to switch probes when you switch measurement modes. Three point pH calibration with auto buffer recognition and 4 point conductivity calibration (one per range) provide high accuracy.  Features include water-resistant membrane keypad, Auto-off, Hold, and ready indicator.

 

 
OAKTON * Waterproof Turbidity Meter

Portable and highly accurate, this Meter is great for water sampling in the field.  Four-point push-button calibration offers full range accuracy. Sealed optical system with infrared light source ensures high accuracy. Meter is auto ranging from 0 - 1000 NTU.  Power-saving auto off function allows 1000 readings on one set of batteries. Diagnostic error messages let you know if sample isn’t read. Kit includes four primary standards (0.02, 20.0, 100 and 800 NTU), two empty cuvettes with light shield caps.

 

 
TSI * VelociCalc Model 8347

Measures air velocity and temperature, calculate flow rate, perform multi-value averaging, and determine minimum and maximum readings also measure humidity along with dew point and wet bulb temperature calculations.

 

 
6644YSI * 556 Multiprobe System

Rugged, reliable and waterproof, the YSI 556 MPS (Multiprobe System) combines the versatility of an easy-to-use, easy-to-read handheld unit with all the functionality of a multi-parameter system. Featuring a waterproof IP-67, impact-resistant case, the YSI 556 MPS simultaneously measures dissolved oxygen, pH, conductivity, temperature, and ORP. The YSI 556 MPS assists the user in conforming to GLP standards

 

 
PROACTIVE * Tempest Pump

The ProActive Low Flow Sampling Controller is engineered specifically for the level by simply connecting it to a 12 volt battery . Its reliable design is suitable for continuous sampling or purging of groundwater wells. The Tempest can pass sand, small rocks and debris without getting clogged or damaging the pump motors. The Tempest can also be used for Low Flow Sampling when paired with the Controller Described below

 

 
PROACTIVE * Low Flow Controller

The ProActive Low Flow Sampling Controller is engineered specifically for the Cyclone, Mini-Typhoon, Typhoon, Tempest, Twister, Mini-Monsoon and Super-Twister.  With the Low Flow Sampling Controller the user can precisely control the water discharge with the turn of a knob. The Low Flow Sampling Controller is used to achieve low flow sampling as low as 40ml/min. in accordance to EPA field sampling guidelines.   Simply hook the controller to a car battery and connect the pump to the Controller. Set dial to low, turn on device and then increase the flow to the desired flow rate.

 

 
DURHAM GEO * Hand Auger

Durham Geo Slope Indicator Hand Auger with unique hard-faced and cupped blades is ideal for boring shallow holes in fine grained soils. Heavy gauge, heat treated carbon steel bucket for long life with cupped blades of unique design to facilitate hole advancement.

Zinc electroplated for rust resistance. Quick connect pins avoid use of wrenches. Special “windowed bucket” is available for use in sticky clay soils.

 

 
DURHAM GEO * Peristaltic Pump

The compact TR-200 is self contained and does not require an external controller or power source. At only 10 lb, this pump is light and small enough to carry anywhere. The pump tubing is easy to inspect, clean and replace. The rugged, water-tight enclosure is made of impact and corrosion resistant ABS plastic to withstand demanding work conditions. 0 - 500 mL/min with 25 ft of ¼” OD suction tube and o ft head. Flow will vary with battery condition and head.

 

 
DURHAM GEO * Sample Plus Pump

The Sample Plus™ Single Stage is a variable speed, electrical submersible pumping system designed for sampling and purging 2 in and larger wells. The Sample Plus™  will maintain flow rates from 100 ml to 5.5 gpm, making the system ideal for purging and low flow sampling. The pumps are specifically designed for use in wells relatively  free of silts and sands. It should not be used for well development.

100ft or 200ft models stocked. Longer models available with request.

 

 
DURHAM GEO * Power Inverter

The pump is powered and controlled by the TR-394 (115 V) Sample Plus™ Single Stage Pump Inverter. The low power requirements of the Sample Plus™ pump results in a smaller generator being required (1250 W). The inverter’s digital display of the speed makes it easier to produce repeatable flow rates.